| Cos-One : "Brand" |
| |
|
|
|
 |
Advantages of Power Factor Correction :
- Avoid p.f. penalty imposed by electricity board due to poor power factor.
- Reduction of M.D. (KVA demand), thereby reduced bill and increased capacity.
- Awail p.f. rebate on demand & energy charges in elect bill upto 7.5 %.
- Reduced load current, distribution losses, heating of transformers & cables.
- Increased service life of all electrical equipments in the plant.
- Shortest payback period on investment – from 2 to 18 months.
|
Advantages of Harmonic filtering :
-
Reduction in overheating of transformers (k-factor), switchgears,motors and cables
- Reduction in failure of PFC capacitors, PLCs, motors, transformers and cables
- Lesser current in neutral conductors
- Prevention of mal-operation of electronic equipments and cards
- No errors in energy meters, counters, PLCs and other sensitive equipments
- No production downtime, thus increased profitability for the industry
- Avoid nuisance tripping of breakers, fuses and protection relays.
|
|
| Automatic Power Factor Correction Panels |
Intelligent microprocessor control - Contactor switched APFC
|
|
Product range:
10 to 2400 KVAR / 110 to 850 VAC / 1 or 3 phase
Available with /without harmonic filters |
| Qutstanding Features |
- Intelligent APFC with microprocessor based controller and SIEMENS/EPCOS components
- Automatic switching of PFC capacitors based on load variations of plant and KVAr required.
- Designed to achieve p.f. near to unity to get the optimum power utilization and reduced demand
- Systems available for balanced as well as un-balanced loads, 1-ph an 3-phase
- Less maintenance by optimized design, low loss and has long service life
- Display of all major electrical parameters like KW, KVAr, KVA, p.f., harmonics, V, I , Hz, etc.
- Alarm output for low p.f., capacitor failure, overcompensation, over temp., undervoltage, etc.
- Auto/Manual Mode facility, back-up fuse/MCCB protection for each capacitor feeders
- Switching counter &operation period time counter for each individual capacitor feeders
- Light weight, compact design suitable for ambient temperature upto 55 deg C
- Enclosures with CRCA sheet steel, pretreated for anti-rust and powder coated
- Data logging /operational facility through GSM mobile, ethernet, RS485/232
- Manufactured as per relevant national and international standards.
- PFC capacitors MPP PhiCap Normal & Heavy Duty, MKK PhaseCap Gas Filled and APP type capacitors
- Iron core harmonic filter reactors with Copper/Aluminum winding, low loss, high linearity
- Intelligent microprocessor based APFC & RTPFC controllers, Capacitor duty contactors, Thyristor swicthes
|
|
| Thyristor Switched RTPFC Panels |
|
Thyristor switched Real time PFC - High speed electronically switched |
Product range :
18 to 1800 KVAR / 110 to 525 VAC / 1 or 3 phase
Available with /without harmonic filters
|
Outstanding Features
- Latest thyristor zero-voltage switching system – cycle-to-cycle correction
High speed – transient
- free switching of PFC capacitors within 40 to 60 millisec.
- Designed to achieve precisely unity p.f. near to unity to get max pf rebate and avoid leading p.f.
- Suitable for rolling mills, welding loads, DG set loads, ports, steel mills, cement and paper, etc
- Systems available for balanced as well as un-balanced loads, 1-ph an 3-phase
Enhanced capacitor life due to transient-free, zero inrush current switching
- Maintenance-free because of static switching, no wear and tear of contactors
Display of all major electrical parameters like KW, KVAr, KVA, p.f., harmonics, V, I , Hz, etc.
- Alarm output for low p.f., capacitor failure, overcompensation, over temp., undervoltage, etc.
Auto/Manual Mode facility, back-up fuse/MCCB protection for each capacitor feeders
- Hybrid version also available – contactor + thyristor switching for cost effectiveness.
- Enclosures with CRCA sheet steel, pretreated for anti-rust and powder coated
- Data logging /operational facility through GSM mobile, ethernet, RS485/232 - optional
|
|
| Harmonic Filtering systems |
| Contactor / Thyristor switched Tuned / Detuned harmonic filtering systems |
 |
Product range :
10 to 2400 KVAR / 110 to 850 VAC |
Outstanding Features
-
Tuned as well as detuned (ant-resonance) filtering systems
- Designed for mitigating harmonics of 3rd, 5th, 7th, 11th, 13th and right up to 31st order harmonics
- Consisting of low-loss, high linearity harmonic filter reactors and PFC capacitors
- Extremely rugged design for severe harmonic contaminated loads like steel mills, IT industries, etc.
- Forced cooling system designed to limit the temperature rise of the filtering system
- Enclosures with CRCA sheet steel, pretreated for anti-rust and powder coated
- Data logging /operational facility through GSM mobile, ethernet, RS485/232 - optional
|
|
| |
|
|
|
|
|